From the manufacturer:
Fiber Testing – Multimode MPO/MTP Light Source/ Power Meter Kit (Certifier40G only)
Autotest
Test time - 5 s
Test parameters - Loss per channel in graphical and tabular format, polarity of link (A, B, C, Custom), pass/fail against user set limit
MPO link configurations All 12 fibers or user-selected channels
Test configurations MPO-MPO
MPO-SC/LC (Requires duplex multimode fiber adapter onlocal unit)
MPO Light Source Adapter
Fiber/connector type Multimode MPO (Type A, pinned)
Wavelength 830 – 860 nm
MPO Power Meter Adapter
Fiber/connector type Multimode MPO (TypeA,pinned)
Loss Measurement
Dynamic range 15 dB
Accuracy ±0.2 dB
Verification period Yearly verification recommended(copper calibration stored onmainframe, fiber calibrationstored on fiber test probes)