FLUKE 345 PQ Power Quality CLAMP METER 2000 A 600 V with Accessories
Model: 345
Condition: Used
In stock: 0
SKU: 2989 7A01
- Current Clamps
- Electronic T&M
Choose options




















Condition: Used
This Fluke 345 Power Quality Clamp Meter is in very good condition and is supplied complete with leads and carry case as pictured. A versatile and capable instrument suited to power quality analysis, VFD troubleshooting, harmonics measurement and load studies.
Included with this unit:
• Test leads
• Carry case
The Fluke 345 Power Quality Clamp Meter is a multi-function instrument combining the capabilities of a clamp meter, oscilloscope, data logger and digital power meter in a single handheld device. Designed for troubleshooting and logging power quality on switching electronic loads including variable frequency drives, UPS systems and high-efficiency lighting, the 345 features a Hall Effect clamp jaw enabling DC current measurement without breaking the circuit.
A bright backlit colour display provides clear visualisation of waveforms, harmonic spectra and logged trends. The built-in low-pass filter removes high-frequency noise for accurate measurements on distorted waveforms, while the high EMC immunity design ensures reliable performance in electrically noisy environments. Internal memory supports long-term power quality logging from minutes to over one month, enabling identification of intermittent faults and trend analysis. Data can be downloaded via USB using the included PowerLog software for reporting and further analysis.
Key capabilities include harmonics measurement and logging (displayed digitally or graphically), inrush current capture (3 to 300 seconds), DC ripple measurement for battery systems, and built-in balanced three-phase power measurement.
Typical Applications:
• Setup and troubleshooting of variable frequency drives and UPS systems
• Harmonics analysis to identify equipment-damaging distortion
• Inrush current capture for nuisance tripping investigations
• Load studies prior to adding electrical loads
• Battery and DC system verification via DC ripple measurement
Specifications:
AC Current Range: 1 A to 2000 A
DC Current Range: 1 A to 2000 A
AC Voltage Range: Up to 600 V
DC Voltage Range: Up to 600 V
Current Measurement Technology: Hall Effect clamp
Harmonics Analysis: Up to 50th harmonic
Inrush Capture Duration: 3 seconds to 300 seconds
Data Interface: USB
Display: Backlit colour LCD
Logging Duration: Minutes to over one month
Software: PowerLog (PC application)
Power Supply: Battery or mains (via power adapter for extended logging)
For three-phase applications, Fluke recommends the 1735 or 43-Series II power analysers.
Fluke 345 Power Quality Clamp Meter User Manual (English): Download PDF
Fluke 345 Power Quality Clamp Meter Product Datasheet: Download PDF
Product Overview
Condition: Used
This Fluke 345 Power Quality Clamp Meter is in very good condition and is supplied complete with leads and carry case as pictured. A versatile and capable instrument suited to power quality analysis, VFD troubleshooting, harmonics measurement and load studies.
Included with this unit:
• Test leads
• Carry case
Manufacturer's Description
The Fluke 345 Power Quality Clamp Meter is a multi-function instrument combining the capabilities of a clamp meter, oscilloscope, data logger and digital power meter in a single handheld device. Designed for troubleshooting and logging power quality on switching electronic loads including variable frequency drives, UPS systems and high-efficiency lighting, the 345 features a Hall Effect clamp jaw enabling DC current measurement without breaking the circuit.
A bright backlit colour display provides clear visualisation of waveforms, harmonic spectra and logged trends. The built-in low-pass filter removes high-frequency noise for accurate measurements on distorted waveforms, while the high EMC immunity design ensures reliable performance in electrically noisy environments. Internal memory supports long-term power quality logging from minutes to over one month, enabling identification of intermittent faults and trend analysis. Data can be downloaded via USB using the included PowerLog software for reporting and further analysis.
Key capabilities include harmonics measurement and logging (displayed digitally or graphically), inrush current capture (3 to 300 seconds), DC ripple measurement for battery systems, and built-in balanced three-phase power measurement.
Typical Applications:
• Setup and troubleshooting of variable frequency drives and UPS systems
• Harmonics analysis to identify equipment-damaging distortion
• Inrush current capture for nuisance tripping investigations
• Load studies prior to adding electrical loads
• Battery and DC system verification via DC ripple measurement
Specifications:
AC Current Range: 1 A to 2000 A
DC Current Range: 1 A to 2000 A
AC Voltage Range: Up to 600 V
DC Voltage Range: Up to 600 V
Current Measurement Technology: Hall Effect clamp
Harmonics Analysis: Up to 50th harmonic
Inrush Capture Duration: 3 seconds to 300 seconds
Data Interface: USB
Display: Backlit colour LCD
Logging Duration: Minutes to over one month
Software: PowerLog (PC application)
Power Supply: Battery or mains (via power adapter for extended logging)
For three-phase applications, Fluke recommends the 1735 or 43-Series II power analysers.
Resources
Fluke 345 Power Quality Clamp Meter User Manual (English): Download PDF
Fluke 345 Power Quality Clamp Meter Product Datasheet: Download PDF
ISO Certified
We are proud to hold the ISO 9001:2015 certification by a UKAS accredited body.
Sell Your Equipment
Receive best prices for your un-used/surplus equipment. Talk to one of our experts for a hassle-free transaction
Worldwide delivery
We deliver on an express service globally with most packages delivered in less than a week
Customer Satisfaction
We pride ourselves in providing an excellent service from start to finish.
Top Rated Seller
Our feedback says it all! We have shipped to over 100 countries all over the world and our customers couldn't be happier!