Draeger Oxylog 3000 with Options & Power Adapter / Hose Oper. Hours 476 MFD 2008
Model: 3000
Condition: Used
In stock: 0
SKU: 3259 1A04
- calibration equipment
- Laboratory
- oxylog
Choose options









Condition: Used
This tested and working Dräger Oxylog 3000 (manufactured 2008) presents with multiple enabled ventilation modes active, making it ready for a wide range of patient scenarios straight from the box. With only 476 operating hours recorded, this is a low-hours example of one of the most widely trusted transport ventilators in emergency and critical care.
Included with this unit:
• Power adapter
• Ventilation hose
The Dräger Oxylog 3000 is a time-cycled, volume-controlled and pressure-controlled emergency and transport ventilator for patients requiring mandatory or assisted ventilation with a tidal volume from 50 mL upwards. Designed for use both in-hospital and in the field, it supports a wide range of patients and medical conditions through volume- and pressure-based ventilation modes for controlled, synchronised or spontaneous ventilation.
The Oxylog 3000 is driven by a high-pressure gas supply — no internal blower is required — making the unit light, compact and easy to carry. It is spray-proof, drop-resistant (rated to withstand falls from up to 75 cm), suitable for use in helicopters and fixed-wing aircraft, and functions across extreme temperature ranges.
Ventilation Modes: VC-CMV (IPPV), VC-AC (IPPVAssist), VC-SIMV, Spn-CPAP (/PS), PC-BIPAP
Tidal Volume: 0.05 to 2.0 L (BTPS)
Respiratory Rate: 2 to 60 breaths/min (VC-SIMV, PC-BIPAP); 5 to 60 breaths/min (VC-CMV, VC-AC); 12 to 60 breaths/min for apnoea ventilation
Oxygen Concentration (FiO2): 40 to 100 Vol.% (continuously adjustable)
Inspiratory Pressure: PEEP + 3 to +55 mbar
PEEP/CPAP: 0 to 20 mbar
Inspiratory Time: 0.2 to 10 seconds
Inspiratory Flow: Up to 100 L/min at supply pressures >350 kPa / 51 PSI; 80 L/min at <350 kPa; 39 L/min at <270 kPa
Apnoea Alarm Time: Adjustable 15 to 60 seconds
Battery: Smart lithium-ion internal battery; up to 4 hours operation
Operating Temperature: -20 to +50°C (basic device)
Atmospheric Pressure Range: 570 to 1200 hPa (17 to 35 in. Hg)
Relative Humidity: 5 to 95%
EMC: In accordance with IEC/EN 60601-1-2:2001 and ISO 10651-3
Airworthiness: RTCA DO-160D, sections 7, 8 & 21
Mechanical Strength: MIL STD 810F, method 514.5
MDD Classification: Class IIb
Optional features include AutoFlow (volume-controlled ventilation with minimised peak inspiratory pressure), 100% O2 flush, O2 inhalation, and integrated mainstream capnography (etCO2 monitoring). The intuitive Dräger rotary knob interface follows the select-adjust-confirm paradigm, with a large high-contrast display showing real-time flow and pressure curves, alarm signals, and all ventilation parameters at a glance.
Dräger Oxylog 3000 Instructions for Use (SW 1.n) — hosted by emed.ie: Download PDF
Dräger Oxylog 3000 Instructions for Use — hosted by jimcontent.com: Download PDF
Dräger Oxylog 3000 plus Instructions for Use (SW 1.n) — official Dräger PDF: Download PDF
Dräger Oxylog 3000 plus Product Information Brochure — official Dräger PDF: Download PDF
Dräger Oxylog 3000 plus Datasheet (EN, North America) — official Dräger PDF: Download PDF
Product Overview
Condition: Used
This tested and working Dräger Oxylog 3000 (manufactured 2008) presents with multiple enabled ventilation modes active, making it ready for a wide range of patient scenarios straight from the box. With only 476 operating hours recorded, this is a low-hours example of one of the most widely trusted transport ventilators in emergency and critical care.
Included with this unit:
• Power adapter
• Ventilation hose
Manufacturer's Description
The Dräger Oxylog 3000 is a time-cycled, volume-controlled and pressure-controlled emergency and transport ventilator for patients requiring mandatory or assisted ventilation with a tidal volume from 50 mL upwards. Designed for use both in-hospital and in the field, it supports a wide range of patients and medical conditions through volume- and pressure-based ventilation modes for controlled, synchronised or spontaneous ventilation.
The Oxylog 3000 is driven by a high-pressure gas supply — no internal blower is required — making the unit light, compact and easy to carry. It is spray-proof, drop-resistant (rated to withstand falls from up to 75 cm), suitable for use in helicopters and fixed-wing aircraft, and functions across extreme temperature ranges.
Ventilation Modes: VC-CMV (IPPV), VC-AC (IPPVAssist), VC-SIMV, Spn-CPAP (/PS), PC-BIPAP
Tidal Volume: 0.05 to 2.0 L (BTPS)
Respiratory Rate: 2 to 60 breaths/min (VC-SIMV, PC-BIPAP); 5 to 60 breaths/min (VC-CMV, VC-AC); 12 to 60 breaths/min for apnoea ventilation
Oxygen Concentration (FiO2): 40 to 100 Vol.% (continuously adjustable)
Inspiratory Pressure: PEEP + 3 to +55 mbar
PEEP/CPAP: 0 to 20 mbar
Inspiratory Time: 0.2 to 10 seconds
Inspiratory Flow: Up to 100 L/min at supply pressures >350 kPa / 51 PSI; 80 L/min at <350 kPa; 39 L/min at <270 kPa
Apnoea Alarm Time: Adjustable 15 to 60 seconds
Battery: Smart lithium-ion internal battery; up to 4 hours operation
Operating Temperature: -20 to +50°C (basic device)
Atmospheric Pressure Range: 570 to 1200 hPa (17 to 35 in. Hg)
Relative Humidity: 5 to 95%
EMC: In accordance with IEC/EN 60601-1-2:2001 and ISO 10651-3
Airworthiness: RTCA DO-160D, sections 7, 8 & 21
Mechanical Strength: MIL STD 810F, method 514.5
MDD Classification: Class IIb
Optional features include AutoFlow (volume-controlled ventilation with minimised peak inspiratory pressure), 100% O2 flush, O2 inhalation, and integrated mainstream capnography (etCO2 monitoring). The intuitive Dräger rotary knob interface follows the select-adjust-confirm paradigm, with a large high-contrast display showing real-time flow and pressure curves, alarm signals, and all ventilation parameters at a glance.
Resources
Dräger Oxylog 3000 Instructions for Use (SW 1.n) — hosted by emed.ie: Download PDF
Dräger Oxylog 3000 Instructions for Use — hosted by jimcontent.com: Download PDF
Dräger Oxylog 3000 plus Instructions for Use (SW 1.n) — official Dräger PDF: Download PDF
Dräger Oxylog 3000 plus Product Information Brochure — official Dräger PDF: Download PDF
Dräger Oxylog 3000 plus Datasheet (EN, North America) — official Dräger PDF: Download PDF
ISO Certified
We are proud to hold the ISO 9001:2015 certification by a UKAS accredited body.
Sell Your Equipment
Receive best prices for your un-used/surplus equipment. Talk to one of our experts for a hassle-free transaction
Worldwide delivery
We deliver on an express service globally with most packages delivered in less than a week
Customer Satisfaction
We pride ourselves in providing an excellent service from start to finish.
Top Rated Seller
Our feedback says it all! We have shipped to over 100 countries all over the world and our customers couldn't be happier!