{"product_id":"optomed-smartscope-m5-handheld-fundus-camera-ey4-cradle-slit-lamp-adapter-1","title":"Optomed SmartScope M5 Handheld Fundus Camera + EY4 Cradle Slit Lamp Adapter","description":"\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Used\u003c\/p\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cb style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed SmartScope M5 WIFI Handheld Fundus Camera With Accessories\u003c\/b\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cbr style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003eThe camera has been tested and fully functional. A new battery has been installed.\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cbr style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003eComes in a the original carry case as shown in the pictures.\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cb style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003cbr style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003c\/b\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cb style=\"box-sizing: border-box; line-height: inherit;\"\u003eIncluded in the sale:\u003c\/b\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cul style=\"box-sizing: border-box; line-height: inherit;\"\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed SmartScope M5 Handheld Fundus Camera\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed Smartscope EY4 Retinal Module\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed SmartScope Cradle v1\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003ePower Supply\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eNew Battery\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed Slit Lamp Adapter\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eUSB With Trial Software and Manuals\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eAluminium Carry Case\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: inherit;\"\u003eAll other pictured accessories\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cbr style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cb style=\"box-sizing: border-box; line-height: inherit;\"\u003eProduct Description (from the manufacturer):\u003c\/b\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\u003cbr style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003c\/div\u003e\u003cdiv style='box-sizing: border-box; line-height: inherit; font-family: \"Times New Roman\"; background-color: rgba(255, 255, 255, 0.004);'\u003e\n\u003cp data-start=\"0\" data-end=\"150\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope M5 is a medical digital camera that is used with dedicated optics modules intended to take images of the eye fundus and surface of the eye.\u003c\/p\u003e\n\u003cp data-start=\"152\" data-end=\"205\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSupported optics modules and their intended uses are:\u003c\/p\u003e\n\u003cp data-start=\"207\" data-end=\"226\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eModel: Description:\u003c\/p\u003e\n\u003cp data-start=\"228\" data-end=\"384\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope EY4\u003cbr data-start=\"242\" data-end=\"245\" style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed Smartscope M5 digital camera with EY4 optics module is intended to capture digital images and video of the fundus of the human eye.\u003c\/p\u003e\n\u003cp data-start=\"386\" data-end=\"524\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope FA\u003cbr data-start=\"399\" data-end=\"402\" style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed Smartscope M5 digital camera with FA optics module is intended to capture fluorescein angiograms of the human eye.\u003c\/p\u003e\n\u003cp data-start=\"526\" data-end=\"697\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope ES2\u003cbr data-start=\"540\" data-end=\"543\" style=\"box-sizing: border-box; line-height: inherit;\"\u003eOptomed Smartscope M5 digital camera with ES2 optics module is intended to capture images and video of the surface of the human eye and surrounding areas.\u003c\/p\u003e\n\u003cp data-start=\"699\" data-end=\"860\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope M5 with optics modules is a prescription device: Federal law restricts this device to sale by or on the order of a physician or licensed practitioner.\u003c\/p\u003e\n\u003cp data-start=\"862\" data-end=\"876\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eIntended users\u003c\/p\u003e\n\u003cp data-start=\"878\" data-end=\"1091\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThe device may only be operated by persons who have been properly trained, who are familiar with fundus cameras, ophthalmoscopes, etc., or who have the required knowledge to operate the device or a similar device.\u003c\/p\u003e\n\u003cp data-start=\"1093\" data-end=\"1158\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThis device may only be used in accordance with its intended use.\u003c\/p\u003e\n\u003cp data-start=\"1160\" data-end=\"1187\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eIntended patient population\u003c\/p\u003e\n\u003cp data-start=\"1189\" data-end=\"1269\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eAll patients may be imaged with Smartscope M5 digital camera with optics module.\u003c\/p\u003e\n\u003cp data-start=\"1271\" data-end=\"1288\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eClinical benefits\u003c\/p\u003e\n\u003cp data-start=\"1290\" data-end=\"1583\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThe images captured with Smartscope M5 support health care professionals with detecting, monitoring, and screening of conditions visible in the human fundus. The applicable specialties include but are not limited to ophthalmology, optometry, diabetology, neurology, pediatry, and primary care.\u003c\/p\u003e\n\u003cp data-start=\"1585\" data-end=\"1773\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eGood image quality together with the wide field of view (40 degrees) and ability to capture images from different parts of the retina enable accurate and comprehensive retinal examination.\u003c\/p\u003e\n\u003cp data-start=\"1775\" data-end=\"2020\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThe small size and low weight of the device allow easy transportation and use in different locations. These features help to reach wider populations and capturing of images of people who may not be able to sit still during the imaging procedure.\u003c\/p\u003e\n\u003cp data-start=\"2022\" data-end=\"2034\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003ePage 7 of 55\u003c\/p\u003e\n\u003cp data-start=\"2036\" data-end=\"2286\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eDevice’s usability and possibility of non-mydriatic imaging improve the operators’ and target population’s experience of the process. These features lead to broader acceptability among the target population and faster workflow and patient management.\u003c\/p\u003e\n\u003cp data-start=\"2288\" data-end=\"2534\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eConnectivity and transfer of digital images improve accessibility of eye health services. They enable the use of tele-medicine and automated image analysis, which both can streamline the workflow. This has direct positive impact on public health.\u003c\/p\u003e\n\u003col start=\"2\" data-start=\"2536\" data-end=\"2602\" style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003cli data-start=\"2536\" data-end=\"2602\" style=\"box-sizing: border-box; line-height: inherit;\"\u003e\u003cp data-start=\"2539\" data-end=\"2602\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eContraindications for use of the optics modules EY4, FA and ES2\u003c\/p\u003e\u003c\/li\u003e\u003c\/ol\u003e\n\u003cp data-start=\"2604\" data-end=\"2868\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eBecause prolonged intense light exposure can damage the retina, the use of the device for ocular examination should not be unnecessarily prolonged, and the brightness setting should not exceed what is needed to provide clear visualization of the target structures.\u003c\/p\u003e\n\u003cp data-start=\"2870\" data-end=\"3089\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThe retinal exposure dose for a photochemical hazard is a product of the radiance and the exposure time. If the value of radiance were reduced in half, twice the time would be needed to reach the maximum exposure limit.\u003c\/p\u003e\n\u003cp data-start=\"3091\" data-end=\"3411\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eWhile no acute optical radiation hazards have been identified for direct or indirect ophthalmoscopes, it is recommended that the intensity of light directed into the patient's eye be limited to the minimum level which is necessary for diagnosis. Infants and persons with aphakia or diseased eyes will be at greater risk.\u003c\/p\u003e\n\u003cp data-start=\"3413\" data-end=\"3693\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eThe risk may also be increased if the person being examined has had any exposure with the same instrument or any other ophthalmic instrument using a visible light source during the previous 24 hours. This will apply particularly if the eye has been exposed to retinal photography.\u003c\/p\u003e\n\u003cp data-start=\"3695\" data-end=\"4040\" data-is-last-node=\"\" data-is-only-node=\"\" style=\"box-sizing: border-box; line-height: inherit; margin: 15px 0px;\"\u003eSmartscope EY4, FA and ES2 are classified as Group 2 based on standard ISO 15004-2:2007. Smartscope FA module has also been classified as Group 1 based on ANSI Z80.36-2016. The daily usage time and maximum allowed number of pulses is calculated based on optical classification results according to standard ISO 15004-2:2007 and ANSI Z80.36-2016.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Optomed","offers":[{"title":"Default Title","offer_id":57623135060350,"sku":"7744 3B02 BM07","price":1228.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/9492\/9575\/files\/57_b650cfd9-7d4b-4fe6-aa87-690a5273cd10.jpg?v=1782728105","url":"https:\/\/www.ttinstruments.com\/products\/optomed-smartscope-m5-handheld-fundus-camera-ey4-cradle-slit-lamp-adapter-1","provider":"TT Instruments","version":"1.0","type":"link"}