{"product_id":"kaiser-rxn1-785-raman-spectrometer-system-w-laser-module-analyser-head-2008","title":"Kaiser Rxn1-785 Raman Spectrometer System w\/ Laser Module + Analyser Head 2007","description":"\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e For parts or not working\u003c\/p\u003e\n\u003cdiv\u003e\u003cb\u003e\u003cspan style=\"color: #0039f3;\"\u003eINSTRUMENT WILL BE SHIPPED ON A PALLET. PLEASE CONTACT US FOR AN ACCURATE SHIPPING QUOTE PRIOR TO PLACEING AN ORDER.\u003c\/span\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eKaiser Rxn1-785 Raman Spectrometer System w\/ Laser Module + Analyser Head 2007\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003ePowers on, passes self test. No further testing performed. Due to interlock unable to test laser therefore sold for parts.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003eIncluded in the sale:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli data-start=\"22\" data-end=\"100\"\u003e\n\u003cp data-start=\"24\" data-end=\"100\"\u003eKaiser Optical Systems RamanRxn1-785 Raman spectrometer main unit (RXN1-785)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"101\" data-end=\"173\"\u003e\n\u003cp data-start=\"103\" data-end=\"173\"\u003eRamanRxn1 analyser head \/ spectrograph with CCD detector (as pictured)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cb\u003eProduct Description (from the manufacturer):\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cp data-start=\"0\" data-end=\"69\"\u003eThe RamanRxn1TM instrument represents Kaiser’s analyser for research.\u003c\/p\u003e\n\u003cp data-start=\"71\" data-end=\"537\"\u003eRaman spectroscopy provides the chemical specificity of a mid-IR analyser with the ease of sampling of a near-IR analyser. The Raman spectrum contains features that are ideal for fast qualitative and robust quantitative analyses, often without the need for multivariate techniques. The sharp Raman peaks can often be interpreted in terms of individual chemical moieties, thus providing an insight into the chemistry of a reaction and the extent of reaction progress.\u003c\/p\u003e\n\u003cp data-start=\"539\" data-end=\"1215\"\u003eThis instrument is a simple to use, compact, turn-key Raman spectrometer system that incorporates the laser, spectrograph, and CCD in a compact base module. The RamanRxn1TM instrument is based on Kaiser’s award winning f\/1.8 axial transmissive spectrograph. The f\/1.8 design is optically efficient and allows more than six times more light to be collected than traditional Czerny-Turner spectrograph designs. In conjunction with a high-performance 1024 × 256 element CCD detector and Kaiser’s proprietary HoloPlexTM grating technology, the RamanRxn1TM spectrometer is capable of providing fast, simultaneous, full spectral collection of Raman data at high spectral resolution.\u003c\/p\u003e\n\u003cp data-start=\"1217\" data-end=\"1624\"\u003eThe RamanRxn1TM spectrometer allows simple grating replacement using pre-aligned grating modules. The capability to change gratings allows users experimental flexibility for lower or higher resolution spectroscopy, or to use gratings designed for specific application. The glass-encapsulated holographic transmission design provides experimental high-performance and operator ruggedness to the spectrograph.\u003c\/p\u003e\n\u003cp data-start=\"1626\" data-end=\"2229\"\u003eSampling optimisation is provided for by utilising high performance fibre-coupled accessories; the AirHeadTM for gas-phase monitoring, the MR Probe probe head for in situ liquids or non-contact solids monitoring, the MK II for Raman depolarisation ratio studies, the Raman microprobe for sample visualisation, mapping, or imaging, and the Analytical Sample Compartment for routine laboratory or quality assurance purposes. Fibre optic sampling and probe technologies enable the RamanRxn1TM instrument to analyse static laboratory samples or real time in situ sample volumes ranging from 5 mL to gallons.\u003c\/p\u003e\n\u003cp data-start=\"2231\" data-end=\"2597\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eWhen used in conjunction with Kaiser’s Raman Calibration Accessory and protocols, the RamanRxn1TM analyser can produce wavelength independent databases, chemical models, and band assignments that may be transferred between instruments and laboratories. The RamanRxn SystemsTM suite of analysers is ideal for analysing, monitoring, and controlling chemical processes.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Kaiser","offers":[{"title":"Default Title","offer_id":56936802320766,"sku":"8136 2B03 BM11","price":2507.5,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/9492\/9575\/files\/kaiser-rxn1-785-raman-spectrometer-system-w-laser-module-analyser-497.webp?v=1776096805","url":"https:\/\/www.ttinstruments.com\/products\/kaiser-rxn1-785-raman-spectrometer-system-w-laser-module-analyser-head-2008","provider":"TT Instruments","version":"1.0","type":"link"}